Remote Control System
RC-100
All Sport Operation Manual
ED-15133 Rev 9 11 March 2015
201 Daktronics Drive PO Box 5128 Brookings, SD 57006-5128
Tel: 1-800-DAKTRONICS (1-800-325-8766) Fax: 605-697-4746
www.daktronics.com/support
Vue de la page 0
1 2 3 4 5 6 ... 44 45

Résumé du contenu

Page 1

Remote Control System RC-100 All Sport Operation Manual ED-15133 Rev 9 – 11 March 2015 201 Daktronics Drive PO Box 5128 Brookings, SD 57006-5128

Page 2

2 Introduction 1.2 Daktronics Exchange and Repair & Return Programs Exchange Program The Daktronics Exchange Program is a service for quickly

Page 3

Introduction 3 Repair & Return Program For items not subject to exchange, Daktronics offers a Repair & Return Program. To send a part for r

Page 5

RC-100 System Overview 5 Section 2: RC-100 System Overview The RC-100 system allows wireless control of multiple scoring and display applications.

Page 7

RC-100 Base Station 7 Section 3: RC-100 Base Station The RC-100 wireless Base Station is used to communicate with all RC-100 wireless handheld con

Page 8

8 RC-100 Base Station Selecting Functions Refer to Figure 5 for the wireless Base Station circuit board assembly drawing. To access the circuit b

Page 9

RC-100 Base Station 9 Keep in mind the following when using the Gen I mode of operation:  Gen I handheld controllers or Base Stations will not op

Page 10

10 RC-100 Base Station 3.3 Synchronizing Multiple Base Stations and Channel Selection If two or more server Base Stations need to operate at the s

Page 11

RC-100 Base Station 11 Installations with a Central Base Station If the installation includes a central Base Station located approximately 3000&ap

Page 13

12 RC-100 Base Station Installations with Base Station Groups If the installation does not include a central location as described above, or if gro

Page 14

RC-100 Base Station 13 3.4 Server/Client Mode Setting The RC-100 wireless Base Station can operate in either Server Mode or Client Mode, depending

Page 15

14 RC-100 Base Station 3.5 Wireless Base Station LEDs The wireless Base Station circuit board includes several light-emitting diodes (LEDs) for di

Page 16

RC-100 Base Station 15 5 CAN TX Green This LED flashes when Controller Area Network (CAN) data is transmitted to a connected device, such as the Om

Page 18

RC-100 Handheld Controller 17 Section 4: RC-100 Handheld Controller 4.1 Powering the Controller On and Off Using the Keypad  Press and hold th

Page 19

18 RC-100 Handheld Controller 4.4 Operation Modes The RC-100 wireless handheld controller (Figure 2) always operates in one of two modes: Config

Page 20

RC-100 Handheld Controller 19 Setting Power Save Mode Display Action Press <ENTER> to set the power off (idle) time. With this setting

Page 21

20 RC-100 Handheld Controller Signal Strength Indicator Once a connection has been made, the top line of the LCD will show the signal strength (Fig

Page 22

RC-100 Handheld Controller 21 3 Up/Down Arrows These keys are used to navigate through menu choices and make certain selections. Arrows may also be

Page 23

ED-15133 Product 1110 Rev 9 – 11 March 2015 DAKTRONICS, INC. Copyright  2007-2015 All rights reserved. While every

Page 25

All Sport Applications 23 Section 5: All Sport Applications This section provides information about the “All Sport” function of the RC-100 wireles

Page 26

24 All Sport Applications 5.2 Keypad Inserts Keypad inserts allow a single console to control multiple sports and applications. Select the proper

Page 27

All Sport Applications 25 5.3 Common All Sport Application Keys Several All Sport applications provide keys with the same functionality, as descri

Page 28

26 All Sport Applications Start Press <START> (Figure 20) to start the main clock. Applies to: Baseball, Basketball, Clock/Score, Football, P

Page 29

All Sport Applications 27 Display Action This key is typically implemented as an alternate function. After the main clock has been stopped, pres

Page 30

28 All Sport Applications Auto Horn Use the Auto Horn key (Figure 26) to set whether the horn sounds automatically when the main clock reaches 0:00

Page 31

Clock/Score Operation 29 Section 6: Clock/Score Operation Sport Insert: LL-2613 Code: 01 (Use Code 11 for optimized server/client operation.)

Page 33

Volleyball Operation 31 Section 7: Volleyball Operation Sport Insert: 0G-239304 Code: 02 The sport insert drawing is located in Appendix B. If

Page 35

32 Volleyball Operation Reset Game Score Display Action Press <RESET GAME SCORE> followed by <ENTER> to reset both home and guest s

Page 36

Baseball Operation 33 Section 8: Baseball Operation Sport Insert: LL-2605 Code: 03, 23 The sport insert drawing is located in Appendix B. If

Page 37

34 Baseball Operation Hit, Error Display Action Press the <HIT> or <ERROR> key to turn on the Hit or Error indicator or digits. T

Page 38

Play Clock & Pitch Timer Operation 35 Section 9: Play Clock & Pitch Timer Operation Sport Insert: LL-2653 Code: 05 The sport insert d

Page 40

Segment Timer Operation 37 Section 10: Segment Timer Operation Sport Insert: LL-2613 Code: 06 The sport insert drawing is located in Appendi

Page 42

Table of Contents i Table of Contents Section 1: Introduction ...

Page 43

ii Table of Contents New Code (Alternate Function) ... 25 Ne

Page 44

Table of Contents iii Section 11: Tennis Operation ...

Page 45

iv Table of Contents Stop .........

Page 46

Introduction 1 Section 1: Introduction This manual is designed to explain the operation of the Daktronics RC-100 Remote Control System for All Spo

Commentaires sur ces manuels

Pas de commentaire